Significant Changes to the Wind Load Provisions of ASCE 7-22 – Ep 092
The Structural Engineering Channel - En podkast av Mathew Picardal, PE, SE & Rachel Holland, P.E. - Torsdager

Kategorier:
In this episode, we talk to William (Bill) Coulbourne, P.E., F. ASCE, F. SEI, a structural engineering consultant and owner of Coulbourne Consulting, about the key changes in ASCE 7-22 wind load provisions that will impact the design of buildings for wind. Engineering Quotes: Here Are Some of the Questions We Ask Bill: How will the new changes impact the design of buildings for wind loads? Talk to us about the first change, which is the added wind load provisions for tornado wind loads. What does the second change to the wind load provision, that was to remove tabular methods of wind pressures from chapters 27, 28, and 30, involve? The third change was to revise the Component and Cladding charts of pressure coefficients and simplified processes. Can you please talk to us more about that? There were also provisions made for ground-mounted solar arrays. Why were these changes needed and what are some of the potential benefits of ground-mounted solar arrays? Another change was the added wind load provisions for elevated buildings. How will this impact the design process for structural engineers going forward? The last change was the added provisions for rooftop pavers. How will this change affect structural engineers in the field? Do you have any career advice for structural engineers on how they can avoid making costly errors during the design process? Here Are Some of the Key Points Discussed About the Significant Changes to the Wind Load Provisions of ASCE 7-22: The changes to the ASCE 7-22 wind load provisions focus only on the component and cladding loads because they experience higher wind pressure than the rest of the structure. The provisions have been made simpler than in previous provisions by reducing the number of steps needed in the processes of getting the loads on components and cladding. The added provisions for tornado wind loads came about because of the number of severely damaging tornados that have occurred over the past 10 years. Everything about tornado loads can now be found in ASCE 7-22 chapter 32. The development of tornado hazard maps enables us to determine the hazard risk for a tornado in any part of the country. The provision changes focus mainly on risk category 3 and 4 buildings for tornado loads. The tabular methods of wind pressures were removed from the wind load provisions because it was realized that updating all the tables due to small changes was cumbersome, and everyone can do it on their own since the formulas have been in the standard all along. The revision of the Component and Cladding charts of pressure coefficients and simplified processes was done because, on previous revisions, the wind coefficients were driven up due to the smaller areas on the wind charts that were analyzed. Doing this increased the pressure on smaller areas, and lost the distribution factor of wind pressure across larger areas and the load-sharing across multiple fasteners. Now the small areas are capped at 10 square feet and nothing smaller, and the larger areas are now 100, 200, and 300 square feet, with nothing above or in between these values. The provisions for ground-mounted solar arrays were added because there were previously no professional guidelines for wind loads on them. Now, with the help of solar array professionals, provisions have been made for solar arrays. The added wind load provisions for elevated buildings came about because there were no wind load provisions for the underside of elevated buildings. Many engineers previously incorporated the wind provisions for the roof of the buildings into the underside of the building plans. The new provisions give engineers something that is science-based and should be more accurate than what was previously done.